Insulation Calculator

US & Canada

Enter the area and pick the insulation to get the packages or bags to buy, straight from the maker's coverage chart.

Your space

1. Area to insulate

ft
ft

For walls, use the total wall length times the height and leave out big openings like doors and windows. For an attic, the floor length times width.

2. Product

%

Batt widths follow your framing: 15 in batts for 16 in on centre, 23 in for 24 in. The allowance applies to batts only.

Result

0

From the data sheet

From the data sheet

Coverage is copied from each maker's own sheet. Packs vary by store and facing, so check the square footage on the bag you buy.

How the insulation maths works

  • Batts = area × (1 + allowance) ÷ square feet per package, rounded up
  • Blown-in = area ÷ 1,000 × the maker's minimum bags per 1,000 sq ft, rounded up

Batt coverage is the area printed on the package, which is the batt area. In a framed wall the studs take some width too, so a package covers a little more wall than that and the count leans slightly over. Blown-in has no extra allowance: the maker's minimum bag count at the minimum settled depth is what the label R-value rests on.

Recommended R-values in the US

From ENERGY STAR's retrofit table, which it bases on the 2021 IECC, Table R402.1.3. Find your zone on the ENERGY STAR climate zone map.

ENERGY STAR recommended insulation by US climate zone
Zone Attic, uninsulated Attic, with 3 to 4 in Floor
1 R30 R25 R13
2 R49 R38 R13
3 R49 R38 R19
4A and 4B R60 R49 R19
4C, 5 and 6 R60 R49 R30
7 and 8 R60 R49 R38

ENERGY STAR gives walls as advice rather than one number: blow insulation into empty cavities when siding comes off, and add R5 sheathing in zone 3, or R5 to R10 in zones 4 to 8.

Minimum RSI in Canada (NBC 2020)

National Building Code of Canada 2020, Table 9.36.2.6.-A, for houses without a heat recovery ventilator. Zones go by heating degree-days. These are effective values for the whole assembly; R is RSI × 5.678, worked out by us, as the code prints RSI only.

NBC 2020 minimum effective thermal resistance by climate zone, without HRV
Zone Degree-days Ceiling below attic Walls Floors over unheated space
4 under 3000 RSI 6.91 (R39.2) RSI 2.78 (R15.8) RSI 4.67 (R26.5)
5 3000 to 3999 RSI 8.67 (R49.2) RSI 3.08 (R17.5) RSI 4.67 (R26.5)
6 4000 to 4999 RSI 8.67 (R49.2) RSI 3.08 (R17.5) RSI 4.67 (R26.5)
7A 5000 to 5999 RSI 10.43 (R59.2) RSI 3.08 (R17.5) RSI 5.02 (R28.5)
7B 6000 to 6999 RSI 10.43 (R59.2) RSI 3.85 (R21.9) RSI 5.02 (R28.5)
8 7000 or more RSI 10.43 (R59.2) RSI 3.85 (R21.9) RSI 5.02 (R28.5)

With an HRV the code allows less in some zones (Table 9.36.2.6.-B), for example walls at RSI 2.97 in zones 5 to 7A. Provinces adopt the NBC on their own timetable, and NBC 2025 has been published, so confirm the edition with your building department.

Ontario uses its own SB-12. In package A1 (Zone 1), as published by the Ontario government in 2016, attics need nominal R60 (effective R59.22) and above-grade walls nominal R22 (effective R17.03). Nominal is the batt's own R-value.

Coverage per package

Coverage per package or bag, from each maker's data sheet
Product Fits Coverage
R-13 fiberglass batt, 15 in (Johns Manville) 2 × 4 walls, 16 in on centre 106.56 sq ft a package
R-13 fiberglass batt, 23 in (Johns Manville) 2 × 4 walls, 24 in on centre 163.39 sq ft a package
R-19 fiberglass batt, 15 in (Johns Manville) 2 × 6 walls, 16 in on centre 87.18 sq ft a package
R-19 fiberglass batt, 23 in (Johns Manville) 2 × 6 walls, 24 in on centre 133.68 sq ft a package
R-30 fiberglass batt, 16 in (Johns Manville) Attic floors and ceilings, 16 in on centre 58.66 sq ft a package
R-30 fiberglass batt, 24 in (Johns Manville) Attic floors and ceilings, 24 in on centre 88 sq ft a package
R-38 fiberglass batt, 16 in (Johns Manville) Attic floors and ceilings, 16 in on centre 42.66 sq ft a package
R-38 fiberglass batt, 24 in (Johns Manville) Attic floors and ceilings, 24 in on centre 64 sq ft a package
R14 Comfortbatt, 16 in o.c. (ROCKWOOL) 2 × 4 walls, 16 in on centre 59.7 sq ft a package
R22 Comfortbatt, 16 in o.c. (ROCKWOOL) 2 × 6 walls, 16 in on centre 39.8 sq ft a package
R22 Comfortbatt, 24 in o.c. (ROCKWOOL) 2 × 6 walls, 24 in on centre 37.5 sq ft a package
R24 Comfortbatt, 16 in o.c. (ROCKWOOL) 2 × 6 walls, 16 in on centre 29.4 sq ft a package
R24 Comfortbatt, 24 in o.c. (ROCKWOOL) 2 × 6 walls, 24 in on centre 29.7 sq ft a package
R-30 blown fiberglass (Owens Corning AttiCat) Open attic floors 14.6 bags per 1,000 sq ft at 10.75 in
R-38 blown fiberglass (Owens Corning AttiCat) Open attic floors 19 bags per 1,000 sq ft at 13.5 in
R-49 blown fiberglass (Owens Corning AttiCat) Open attic floors 25 bags per 1,000 sq ft at 17 in
R-60 blown fiberglass (Owens Corning AttiCat) Open attic floors 31.5 bags per 1,000 sq ft at 20.5 in
R-30 blown cellulose (Greenfiber SANCTUARY) Open attic floors 36.5 bags per 1,000 sq ft at 8.3 in
R-38 blown cellulose (Greenfiber SANCTUARY) Open attic floors 50.1 bags per 1,000 sq ft at 10.4 in
R-49 blown cellulose (Greenfiber SANCTUARY) Open attic floors 68.5 bags per 1,000 sq ft at 13.3 in
R-60 blown cellulose (Greenfiber SANCTUARY) Open attic floors 83.5 bags per 1,000 sq ft at 16.1 in

Sources: Johns Manville Fiberglass Manufacturers Fact Sheet (BID-380 12/19); ROCKWOOL Residential Building Product Guide, Canada; Owens Corning AttiCat Product Data Sheet (May 2026); Greenfiber SANCTUARY attic chart. Blown cellulose charts depend on the blowing machine, so follow the chart on the bag you buy.

Common questions

How many bags of R-13 insulation for 1,000 sq ft of wall?
At 106.56 sq ft a bag (Johns Manville, 15 in for 16 in studs), 1,000 sq ft with 5% allowance needs 10 bags. Pack sizes vary by brand, so check the square footage printed on yours.
How many bags of R-19 for 1,000 sq ft?
Johns Manville R-19, 15 × 93 in, covers 87.18 sq ft a bag, so 13 bags with 5% allowance. Its sheet notes R-19 squeezed into a 2 × 6 wall gives R-17 to R-18.
How many bags of ROCKWOOL R22 do I need?
ROCKWOOL lists R22 Comfortbatt for 16 in studs at 39.8 sq ft (8 batts) a bag. 1,000 sq ft of wall with 5% allowance takes 27 bags.
How many bags of blown-in insulation for R-49?
For 1,000 sq ft of attic: Owens Corning AttiCat needs at least 25 bags at 17 in deep; Greenfiber SANCTUARY cellulose needs 69 bags at 13.3 in settled. Use the chart for the exact product you buy.
How many bags of AttiCat for a 1,200 sq ft attic at R-60?
The AttiCat sheet calls for 31.5 bags per 1,000 sq ft at R-60, so 1,200 sq ft needs 38 bags, blown at least 20.5 in deep.
What R-value do I need in my attic?
In the US, ENERGY STAR recommends R49 to R60 for an uninsulated attic in zones 2 to 8, and R30 in zone 1. In Canada, NBC 2020 sets ceilings below attics at an effective RSI 6.91 to 10.43 (about R39.2 to R59.2) by zone, without an HRV.
Why are Canadian code values lower than the R on the bag?
They are effective values for the whole wall or ceiling, framing included, where wood studs conduct heat. A nominal R22 batt wall in Ontario's SB-12 package A1 is listed at an effective R17.03. Do not compare a batt's label straight against an NBC 9.36 number.
How do I convert RSI to R-value?
Multiply RSI by 5.678. RSI 3.08 is about R17.5, and RSI 10.43 is about R59.2.